dot-get_Dx.RdD_x: Calculate diffusion coefficient for a given temperature and pressure
.get_Dx(D_0, Temp, eT, P, unitless)Diffusion coefficient at 273.15 K (0 °C) and 101.3246 kPa
Temperature in Kelvin
Exponent for temperature dependence of diffusion
Atmospheric pressure in kPa
Logical. Should function use parameters with units? The function is faster when FALSE, but input must be in correct units or else results will be incorrect without any warning.
Value in m\(^2\)/s of class units
$$D = D_\mathrm{0} (T / 273.15) ^ {eT} (101.3246 / P)$$
According to Montieth & Unger (2013), eT is generally between 1.5 and 2. Their data in Appendix 3 indicate \(eT = 1.75\) is reasonable for environmental physics.
Monteith JL, Unsworth MH. 2013. Principles of Environmental Physics. 4th edition. Academic Press, London.